Loading report..

Highlight Samples

Regex mode off

    Rename Samples

    Click here for bulk input.

    Paste two columns of a tab-delimited table here (eg. from Excel).

    First column should be the old name, second column the new name.

    Regex mode off

      Show / Hide Samples

      Regex mode off

        Export Plots

        px
        px
        X

        Download the raw data used to create the plots in this report below:

        Note that additional data was saved in GSE246156_final_multiQC_report_data when this report was generated.


        Choose Plots

        If you use plots from MultiQC in a publication or presentation, please cite:

        MultiQC: Summarize analysis results for multiple tools and samples in a single report
        Philip Ewels, Måns Magnusson, Sverker Lundin and Max Käller
        Bioinformatics (2016)
        doi: 10.1093/bioinformatics/btw354
        PMID: 27312411

        Save Settings

        You can save the toolbox settings for this report to the browser.


        Load Settings

        Choose a saved report profile from the dropdown box below:

        Tool Citations

        Please remember to cite the tools that you use in your analysis.

        To help with this, you can download publication details of the tools mentioned in this report:

        About MultiQC

        This report was generated using MultiQC, version 1.18

        You can see a YouTube video describing how to use MultiQC reports here: https://youtu.be/qPbIlO_KWN0

        For more information about MultiQC, including other videos and extensive documentation, please visit http://multiqc.info

        You can report bugs, suggest improvements and find the source code for MultiQC on GitHub: https://github.com/ewels/MultiQC

        MultiQC is published in Bioinformatics:

        MultiQC: Summarize analysis results for multiple tools and samples in a single report
        Philip Ewels, Måns Magnusson, Sverker Lundin and Max Käller
        Bioinformatics (2016)
        doi: 10.1093/bioinformatics/btw354
        PMID: 27312411

        A modular tool to aggregate results from bioinformatics analyses across many samples into a single report.

        Report generated on 2026-04-09, 14:50 CDT based on data in: /scratch/g/akwitek/wdemos/GSE246156


        General Statistics

        Showing 192/192 rows and 6/9 columns.
        Sample Name% Alignable, M% AlignedM Aligned% Dups% GCM Seqs
        GSM7863755
        96.8%
        GSM7863755_SRR26501832_1
        73.0%
        49%
        22.9
        GSM7863755_SRR26501832_2
        70.1%
        49%
        22.9
        GSM7863755_STAR
        94.8%
        21.7
        GSM7863756
        97.3%
        GSM7863756_SRR26501831_1
        59.4%
        49%
        21.9
        GSM7863756_SRR26501831_2
        57.8%
        49%
        21.9
        GSM7863756_STAR
        95.8%
        21.0
        GSM7863757
        96.7%
        GSM7863757_SRR26501830_1
        58.2%
        50%
        25.5
        GSM7863757_SRR26501830_2
        56.2%
        50%
        25.5
        GSM7863757_STAR
        95.1%
        24.3
        GSM7863758
        97.3%
        GSM7863758_SRR26501829_1
        70.4%
        50%
        23.2
        GSM7863758_SRR26501829_2
        68.5%
        50%
        23.2
        GSM7863758_STAR
        95.1%
        22.1
        GSM7863759
        97.1%
        GSM7863759_SRR26501828_1
        62.1%
        49%
        21.3
        GSM7863759_SRR26501828_2
        60.8%
        49%
        21.3
        GSM7863759_STAR
        95.2%
        20.3
        GSM7863760
        97.3%
        GSM7863760_SRR26501827_1
        60.6%
        50%
        23.0
        GSM7863760_SRR26501827_2
        59.7%
        50%
        23.0
        GSM7863760_STAR
        95.8%
        22.0
        GSM7863761
        96.7%
        GSM7863761_SRR26501826_1
        76.6%
        50%
        23.0
        GSM7863761_SRR26501826_2
        75.2%
        50%
        23.0
        GSM7863761_STAR
        95.7%
        22.1
        GSM7863762
        96.5%
        GSM7863762_SRR26501825_1
        61.9%
        50%
        23.5
        GSM7863762_SRR26501825_2
        60.3%
        50%
        23.5
        GSM7863762_STAR
        94.8%
        22.3
        GSM7863763
        96.2%
        GSM7863763_SRR26501824_1
        81.9%
        49%
        22.3
        GSM7863763_SRR26501824_2
        80.8%
        49%
        22.3
        GSM7863763_STAR
        94.8%
        21.2
        GSM7863764
        96.5%
        GSM7863764_SRR26501815_1
        53.8%
        50%
        23.3
        GSM7863764_SRR26501815_2
        51.3%
        50%
        23.3
        GSM7863764_STAR
        95.1%
        22.2
        GSM7863765
        97.2%
        GSM7863765_SRR26501814_1
        58.1%
        49%
        22.9
        GSM7863765_SRR26501814_2
        56.6%
        49%
        22.9
        GSM7863765_STAR
        95.8%
        21.9
        GSM7863766
        96.7%
        GSM7863766_SRR26501813_1
        54.9%
        50%
        24.6
        GSM7863766_SRR26501813_2
        51.5%
        50%
        24.6
        GSM7863766_STAR
        95.2%
        23.5
        GSM7863767
        96.7%
        GSM7863767_SRR26501812_1
        72.5%
        49%
        21.1
        GSM7863767_SRR26501812_2
        71.5%
        49%
        21.1
        GSM7863767_STAR
        94.7%
        20.0
        GSM7863768
        97.2%
        GSM7863768_SRR26501811_1
        61.9%
        49%
        23.4
        GSM7863768_SRR26501811_2
        61.1%
        49%
        23.4
        GSM7863768_STAR
        95.5%
        22.4
        GSM7863769
        96.5%
        GSM7863769_SRR26501810_1
        64.8%
        49%
        22.8
        GSM7863769_SRR26501810_2
        63.8%
        49%
        22.8
        GSM7863769_STAR
        95.4%
        21.7
        GSM7863770
        96.6%
        GSM7863770_SRR26501809_1
        57.3%
        50%
        25.3
        GSM7863770_SRR26501809_2
        55.6%
        50%
        25.3
        GSM7863770_STAR
        94.9%
        24.0
        GSM7863771
        97.3%
        GSM7863771_SRR26501808_1
        71.2%
        49%
        21.4
        GSM7863771_SRR26501808_2
        70.9%
        49%
        21.4
        GSM7863771_STAR
        95.3%
        20.4
        GSM7863772
        96.8%
        GSM7863772_SRR26501807_1
        62.4%
        48%
        23.2
        GSM7863772_SRR26501807_2
        61.7%
        48%
        23.2
        GSM7863772_STAR
        95.3%
        22.1
        GSM7863773
        96.5%
        GSM7863773_SRR26501806_1
        74.2%
        49%
        20.7
        GSM7863773_SRR26501806_2
        72.5%
        49%
        20.7
        GSM7863773_STAR
        95.3%
        19.7
        GSM7863774
        96.6%
        GSM7863774_SRR26501805_1
        79.5%
        49%
        22.6
        GSM7863774_SRR26501805_2
        78.5%
        49%
        22.6
        GSM7863774_STAR
        95.3%
        21.5
        GSM7863775
        95.5%
        GSM7863775_SRR26501804_1
        76.9%
        49%
        23.3
        GSM7863775_SRR26501804_2
        75.6%
        49%
        23.3
        GSM7863775_STAR
        94.2%
        21.9
        GSM7863776
        96.8%
        GSM7863776_SRR26501803_1
        54.5%
        50%
        21.0
        GSM7863776_SRR26501803_2
        52.8%
        50%
        21.0
        GSM7863776_STAR
        95.6%
        20.1
        GSM7863777
        97.0%
        GSM7863777_SRR26501802_1
        70.5%
        49%
        21.5
        GSM7863777_SRR26501802_2
        69.4%
        49%
        21.5
        GSM7863777_STAR
        95.8%
        20.6
        GSM7863778
        95.5%
        GSM7863778_SRR26501801_1
        70.7%
        48%
        21.5
        GSM7863778_SRR26501801_2
        69.7%
        48%
        21.5
        GSM7863778_STAR
        94.9%
        20.4
        GSM7863779
        96.4%
        GSM7863779_SRR26501800_1
        65.3%
        50%
        24.8
        GSM7863779_SRR26501800_2
        62.7%
        51%
        24.8
        GSM7863779_STAR
        95.2%
        23.6
        GSM7863780
        96.0%
        GSM7863780_SRR26501799_1
        64.3%
        50%
        24.5
        GSM7863780_SRR26501799_2
        63.4%
        50%
        24.5
        GSM7863780_STAR
        94.0%
        23.0
        GSM7863781
        95.9%
        GSM7863781_SRR26501798_1
        70.4%
        51%
        31.6
        GSM7863781_SRR26501798_2
        65.8%
        51%
        31.6
        GSM7863781_STAR
        94.4%
        29.8
        GSM7863782
        95.8%
        GSM7863782_SRR26501797_1
        69.6%
        50%
        24.0
        GSM7863782_SRR26501797_2
        66.8%
        50%
        24.0
        GSM7863782_STAR
        94.3%
        22.6
        GSM7863783
        96.3%
        GSM7863783_SRR26501796_1
        57.9%
        50%
        20.2
        GSM7863783_SRR26501796_2
        56.0%
        50%
        20.2
        GSM7863783_STAR
        95.1%
        19.2
        GSM7863784
        97.0%
        GSM7863784_SRR26501795_1
        71.4%
        50%
        23.5
        GSM7863784_SRR26501795_2
        70.3%
        50%
        23.5
        GSM7863784_STAR
        94.7%
        22.3
        GSM7863785
        95.5%
        GSM7863785_SRR26501794_1
        66.6%
        50%
        21.0
        GSM7863785_SRR26501794_2
        64.6%
        50%
        21.0
        GSM7863785_STAR
        94.2%
        19.8
        GSM7863786
        95.4%
        GSM7863786_SRR26501793_1
        74.2%
        50%
        24.4
        GSM7863786_SRR26501793_2
        71.9%
        50%
        24.4
        GSM7863786_STAR
        94.2%
        23.0
        GSM7863787
        95.8%
        GSM7863787_SRR26501792_1
        67.0%
        50%
        20.3
        GSM7863787_SRR26501792_2
        64.8%
        50%
        20.3
        GSM7863787_STAR
        92.2%
        18.8
        GSM7863788
        97.0%
        GSM7863788_SRR26501823_1
        56.4%
        50%
        20.1
        GSM7863788_SRR26501823_2
        54.2%
        50%
        20.1
        GSM7863788_STAR
        95.7%
        19.2
        GSM7863789
        96.7%
        GSM7863789_SRR26501822_1
        55.0%
        50%
        24.0
        GSM7863789_SRR26501822_2
        53.9%
        50%
        24.0
        GSM7863789_STAR
        95.6%
        22.9
        GSM7863790
        96.7%
        GSM7863790_SRR26501821_1
        54.5%
        50%
        23.8
        GSM7863790_SRR26501821_2
        53.2%
        50%
        23.8
        GSM7863790_STAR
        95.1%
        22.6
        GSM7863791
        95.5%
        GSM7863791_SRR26501820_1
        67.1%
        50%
        20.4
        GSM7863791_SRR26501820_2
        63.0%
        50%
        20.4
        GSM7863791_STAR
        93.0%
        18.9
        GSM7863792
        96.4%
        GSM7863792_SRR26501819_1
        60.1%
        50%
        24.4
        GSM7863792_SRR26501819_2
        57.7%
        50%
        24.4
        GSM7863792_STAR
        94.9%
        23.1
        GSM7863793
        97.0%
        GSM7863793_SRR26501818_1
        67.4%
        50%
        22.3
        GSM7863793_SRR26501818_2
        66.2%
        50%
        22.3
        GSM7863793_STAR
        94.8%
        21.1
        GSM7863794
        96.5%
        GSM7863794_SRR26501817_1
        60.5%
        50%
        24.7
        GSM7863794_SRR26501817_2
        58.6%
        50%
        24.7
        GSM7863794_STAR
        94.0%
        23.2
        GSM7863795
        97.1%
        GSM7863795_SRR26501816_1
        67.8%
        50%
        22.8
        GSM7863795_SRR26501816_2
        67.1%
        50%
        22.8
        GSM7863795_STAR
        95.5%
        21.8
        GSM7863796
        96.4%
        GSM7863796_SRR26501791_1
        66.8%
        50%
        25.1
        GSM7863796_SRR26501791_2
        64.4%
        50%
        25.1
        GSM7863796_STAR
        94.7%
        23.8
        GSM7863797
        95.9%
        GSM7863797_SRR26501790_1
        58.4%
        50%
        22.3
        GSM7863797_SRR26501790_2
        56.4%
        50%
        22.3
        GSM7863797_STAR
        94.7%
        21.1
        GSM7863798
        96.8%
        GSM7863798_SRR26501789_1
        64.8%
        49%
        23.6
        GSM7863798_SRR26501789_2
        63.5%
        49%
        23.6
        GSM7863798_STAR
        95.3%
        22.5
        GSM7863799
        96.3%
        GSM7863799_SRR26501788_1
        67.3%
        49%
        20.3
        GSM7863799_SRR26501788_2
        64.6%
        49%
        20.3
        GSM7863799_STAR
        95.2%
        19.3
        GSM7863800
        96.3%
        GSM7863800_SRR26501787_1
        55.9%
        50%
        24.8
        GSM7863800_SRR26501787_2
        53.2%
        50%
        24.8
        GSM7863800_STAR
        94.9%
        23.6
        GSM7863801
        96.6%
        GSM7863801_SRR26501786_1
        58.8%
        50%
        24.4
        GSM7863801_SRR26501786_2
        57.3%
        50%
        24.4
        GSM7863801_STAR
        95.7%
        23.3
        GSM7863802
        96.3%
        GSM7863802_SRR26501785_1
        60.2%
        50%
        33.2
        GSM7863802_SRR26501785_2
        56.0%
        50%
        33.2
        GSM7863802_STAR
        95.1%
        31.6

        Rsem

        Rsem RSEM (RNA-Seq by Expectation-Maximization) is a software package forestimating gene and isoform expression levels from RNA-Seq data.DOI: 10.1186/1471-2105-12-323.

        Mapped Reads

        A breakdown of how all reads were aligned for each sample.

        loading..

        Multimapping rates

        A frequency histogram showing how many reads were aligned to n reference regions.

        In an ideal world, every sequence reads would align uniquely to a single location in the reference. However, due to factors such as repeititve sequences, short reads and sequencing errors, reads can be align to the reference 0, 1 or more times. This plot shows the frequency of each factor of multimapping. Good samples should have the majority of reads aligning once.

        loading..

        STAR

        STAR is an ultrafast universal RNA-seq aligner.DOI: 10.1093/bioinformatics/bts635.

        Alignment Scores

        loading..

        FastQ Screen

        Version: 0.15.1

        FastQ Screen allows you to screen a library of sequences in FastQ format against a set of sequence databases so you can see if the composition of the library matches with what you expect.DOI: 10.12688/f1000research.15931.2.

        Mapped Reads

        loading..

        FastQC

        Version: 0.11.9

        FastQC is a quality control tool for high throughput sequence data, written by Simon Andrews at the Babraham Institute in Cambridge.

        Sequence Counts

        Sequence counts for each sample. Duplicate read counts are an estimate only.

        This plot show the total number of reads, broken down into unique and duplicate if possible (only more recent versions of FastQC give duplicate info).

        You can read more about duplicate calculation in the FastQC documentation. A small part has been copied here for convenience:

        Only sequences which first appear in the first 100,000 sequences in each file are analysed. This should be enough to get a good impression for the duplication levels in the whole file. Each sequence is tracked to the end of the file to give a representative count of the overall duplication level.

        The duplication detection requires an exact sequence match over the whole length of the sequence. Any reads over 75bp in length are truncated to 50bp for this analysis.

        loading..

        Sequence Quality Histograms

        The mean quality value across each base position in the read.

        To enable multiple samples to be plotted on the same graph, only the mean quality scores are plotted (unlike the box plots seen in FastQC reports).

        Taken from the FastQC help:

        The y-axis on the graph shows the quality scores. The higher the score, the better the base call. The background of the graph divides the y axis into very good quality calls (green), calls of reasonable quality (orange), and calls of poor quality (red). The quality of calls on most platforms will degrade as the run progresses, so it is common to see base calls falling into the orange area towards the end of a read.

        loading..

        Per Sequence Quality Scores

        The number of reads with average quality scores. Shows if a subset of reads has poor quality.

        From the FastQC help:

        The per sequence quality score report allows you to see if a subset of your sequences have universally low quality values. It is often the case that a subset of sequences will have universally poor quality, however these should represent only a small percentage of the total sequences.

        loading..

        Per Base Sequence Content

        The proportion of each base position for which each of the four normal DNA bases has been called.

        To enable multiple samples to be shown in a single plot, the base composition data is shown as a heatmap. The colours represent the balance between the four bases: an even distribution should give an even muddy brown colour. Hover over the plot to see the percentage of the four bases under the cursor.

        To see the data as a line plot, as in the original FastQC graph, click on a sample track.

        From the FastQC help:

        Per Base Sequence Content plots out the proportion of each base position in a file for which each of the four normal DNA bases has been called.

        In a random library you would expect that there would be little to no difference between the different bases of a sequence run, so the lines in this plot should run parallel with each other. The relative amount of each base should reflect the overall amount of these bases in your genome, but in any case they should not be hugely imbalanced from each other.

        It's worth noting that some types of library will always produce biased sequence composition, normally at the start of the read. Libraries produced by priming using random hexamers (including nearly all RNA-Seq libraries) and those which were fragmented using transposases inherit an intrinsic bias in the positions at which reads start. This bias does not concern an absolute sequence, but instead provides enrichement of a number of different K-mers at the 5' end of the reads. Whilst this is a true technical bias, it isn't something which can be corrected by trimming and in most cases doesn't seem to adversely affect the downstream analysis.

        Click a sample row to see a line plot for that dataset.
        Rollover for sample name
        Position: -
        %T: -
        %C: -
        %A: -
        %G: -

        Per Sequence GC Content

        The average GC content of reads. Normal random library typically have a roughly normal distribution of GC content.

        From the FastQC help:

        This module measures the GC content across the whole length of each sequence in a file and compares it to a modelled normal distribution of GC content.

        In a normal random library you would expect to see a roughly normal distribution of GC content where the central peak corresponds to the overall GC content of the underlying genome. Since we don't know the the GC content of the genome the modal GC content is calculated from the observed data and used to build a reference distribution.

        An unusually shaped distribution could indicate a contaminated library or some other kinds of biased subset. A normal distribution which is shifted indicates some systematic bias which is independent of base position. If there is a systematic bias which creates a shifted normal distribution then this won't be flagged as an error by the module since it doesn't know what your genome's GC content should be.

        loading..

        Per Base N Content

        The percentage of base calls at each position for which an N was called.

        From the FastQC help:

        If a sequencer is unable to make a base call with sufficient confidence then it will normally substitute an N rather than a conventional base call. This graph shows the percentage of base calls at each position for which an N was called.

        It's not unusual to see a very low proportion of Ns appearing in a sequence, especially nearer the end of a sequence. However, if this proportion rises above a few percent it suggests that the analysis pipeline was unable to interpret the data well enough to make valid base calls.

        loading..

        Sequence Length Distribution

        All samples have sequences of a single length (150bp).

        Sequence Duplication Levels

        The relative level of duplication found for every sequence.

        From the FastQC Help:

        In a diverse library most sequences will occur only once in the final set. A low level of duplication may indicate a very high level of coverage of the target sequence, but a high level of duplication is more likely to indicate some kind of enrichment bias (eg PCR over amplification). This graph shows the degree of duplication for every sequence in a library: the relative number of sequences with different degrees of duplication.

        Only sequences which first appear in the first 100,000 sequences in each file are analysed. This should be enough to get a good impression for the duplication levels in the whole file. Each sequence is tracked to the end of the file to give a representative count of the overall duplication level.

        The duplication detection requires an exact sequence match over the whole length of the sequence. Any reads over 75bp in length are truncated to 50bp for this analysis.

        In a properly diverse library most sequences should fall into the far left of the plot in both the red and blue lines. A general level of enrichment, indicating broad oversequencing in the library will tend to flatten the lines, lowering the low end and generally raising other categories. More specific enrichments of subsets, or the presence of low complexity contaminants will tend to produce spikes towards the right of the plot.

        loading..

        Overrepresented sequences by sample

        The total amount of overrepresented sequences found in each library.

        FastQC calculates and lists overrepresented sequences in FastQ files. It would not be possible to show this for all samples in a MultiQC report, so instead this plot shows the number of sequences categorized as overrepresented.

        Sometimes, a single sequence may account for a large number of reads in a dataset. To show this, the bars are split into two: the first shows the overrepresented reads that come from the single most common sequence. The second shows the total count from all remaining overrepresented sequences.

        From the FastQC Help:

        A normal high-throughput library will contain a diverse set of sequences, with no individual sequence making up a tiny fraction of the whole. Finding that a single sequence is very overrepresented in the set either means that it is highly biologically significant, or indicates that the library is contaminated, or not as diverse as you expected.

        FastQC lists all the sequences which make up more than 0.1% of the total. To conserve memory only sequences which appear in the first 100,000 sequences are tracked to the end of the file. It is therefore possible that a sequence which is overrepresented but doesn't appear at the start of the file for some reason could be missed by this module.

        96 samples had less than 1% of reads made up of overrepresented sequences

        Top overrepresented sequences

        Top overrepresented sequences across all samples. The table shows 20 most overrepresented sequences across all samples, ranked by the number of samples they occur in.

        Showing 3/3 rows and 3/3 columns.
        Overrepresented sequenceSamplesOccurrences% of all reads
        TTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT
        39
        1766030
        0.0792%
        TGGCAAGCCAAGGTCACCAGCAGGCAGTGGCTCAGGAACTTGAAGTTGAC
        6
        190840
        0.0086%
        CAGGAAGCAATCATGGTGCTCTCTGCAGATGACAAAACCAACATCAAGAA
        2
        51849
        0.0023%

        Adapter Content

        The cumulative percentage count of the proportion of your library which has seen each of the adapter sequences at each position.

        Note that only samples with ≥ 0.1% adapter contamination are shown.

        There may be several lines per sample, as one is shown for each adapter detected in the file.

        From the FastQC Help:

        The plot shows a cumulative percentage count of the proportion of your library which has seen each of the adapter sequences at each position. Once a sequence has been seen in a read it is counted as being present right through to the end of the read so the percentages you see will only increase as the read length goes on.

        loading..

        Status Checks

        Status for each FastQC section showing whether results seem entirely normal (green), slightly abnormal (orange) or very unusual (red).

        FastQC assigns a status for each section of the report. These give a quick evaluation of whether the results of the analysis seem entirely normal (green), slightly abnormal (orange) or very unusual (red).

        It is important to stress that although the analysis results appear to give a pass/fail result, these evaluations must be taken in the context of what you expect from your library. A 'normal' sample as far as FastQC is concerned is random and diverse. Some experiments may be expected to produce libraries which are biased in particular ways. You should treat the summary evaluations therefore as pointers to where you should concentrate your attention and understand why your library may not look random and diverse.

        Specific guidance on how to interpret the output of each module can be found in the relevant report section, or in the FastQC help.

        In this heatmap, we summarise all of these into a single heatmap for a quick overview. Note that not all FastQC sections have plots in MultiQC reports, but all status checks are shown in this heatmap.

        loading..

        Software Versions

        Software Versions lists versions of software tools extracted from file contents.

        SoftwareVersion
        FastQ Screen0.15.1
        FastQC0.11.9