Loading report..

Highlight Samples

Regex mode off

    Rename Samples

    Click here for bulk input.

    Paste two columns of a tab-delimited table here (eg. from Excel).

    First column should be the old name, second column the new name.

    Regex mode off

      Show / Hide Samples

      Regex mode off

        Export Plots

        px
        px
        X

        Download the raw data used to create the plots in this report below:

        Note that additional data was saved in GSE127000_final_multiQC_report_data when this report was generated.


        Choose Plots

        If you use plots from MultiQC in a publication or presentation, please cite:

        MultiQC: Summarize analysis results for multiple tools and samples in a single report
        Philip Ewels, Måns Magnusson, Sverker Lundin and Max Käller
        Bioinformatics (2016)
        doi: 10.1093/bioinformatics/btw354
        PMID: 27312411

        Save Settings

        You can save the toolbox settings for this report to the browser.


        Load Settings

        Choose a saved report profile from the dropdown box below:

        Tool Citations

        Please remember to cite the tools that you use in your analysis.

        To help with this, you can download publication details of the tools mentioned in this report:

        About MultiQC

        This report was generated using MultiQC, version 1.18

        You can see a YouTube video describing how to use MultiQC reports here: https://youtu.be/qPbIlO_KWN0

        For more information about MultiQC, including other videos and extensive documentation, please visit http://multiqc.info

        You can report bugs, suggest improvements and find the source code for MultiQC on GitHub: https://github.com/ewels/MultiQC

        MultiQC is published in Bioinformatics:

        MultiQC: Summarize analysis results for multiple tools and samples in a single report
        Philip Ewels, Måns Magnusson, Sverker Lundin and Max Käller
        Bioinformatics (2016)
        doi: 10.1093/bioinformatics/btw354
        PMID: 27312411

        A modular tool to aggregate results from bioinformatics analyses across many samples into a single report.

        Report generated on 2026-03-18, 23:14 CDT based on data in: /scratch/g/akwitek/wdemos/GSE127000


        General Statistics

        Showing 159/159 rows and 6/9 columns.
        Sample Name% Alignable, M% AlignedM Aligned% Dups% GCM Seqs
        GSM3619616
        85.3%
        GSM3619616_SRR8618434_1
        60.7%
        47%
        30.2
        GSM3619616_SRR8618434_2
        55.8%
        48%
        30.2
        GSM3619616_STAR
        87.0%
        26.3
        GSM3619617
        83.4%
        GSM3619617_SRR8618435_1
        54.5%
        46%
        32.6
        GSM3619617_SRR8618435_2
        49.4%
        47%
        32.6
        GSM3619617_STAR
        87.2%
        28.5
        GSM3619618
        85.4%
        GSM3619618_SRR8618436_1
        63.5%
        46%
        44.7
        GSM3619618_SRR8618436_2
        58.3%
        47%
        44.7
        GSM3619618_STAR
        87.2%
        38.9
        GSM3619619
        86.3%
        GSM3619619_SRR8618437_1
        70.1%
        47%
        36.7
        GSM3619619_SRR8618437_2
        65.1%
        48%
        36.7
        GSM3619619_STAR
        86.1%
        31.6
        GSM3619620
        88.3%
        GSM3619620_SRR8618438_1
        64.3%
        47%
        33.5
        GSM3619620_SRR8618438_2
        59.1%
        48%
        33.5
        GSM3619620_STAR
        88.6%
        29.7
        GSM3619621
        87.7%
        GSM3619621_SRR8618439_1
        74.9%
        47%
        36.7
        GSM3619621_SRR8618439_2
        70.6%
        48%
        36.7
        GSM3619621_STAR
        86.0%
        31.5
        GSM3619622
        88.4%
        GSM3619622_SRR8618440_1
        67.6%
        46%
        31.1
        GSM3619622_SRR8618440_2
        63.0%
        47%
        31.1
        GSM3619622_STAR
        87.9%
        27.3
        GSM3619623
        87.9%
        GSM3619623_SRR8618441_1
        60.7%
        47%
        37.1
        GSM3619623_SRR8618441_2
        55.8%
        47%
        37.1
        GSM3619623_STAR
        89.1%
        33.1
        GSM3619624
        81.9%
        GSM3619624_SRR8618442_1
        69.8%
        46%
        40.9
        GSM3619624_SRR8618442_2
        64.9%
        47%
        40.9
        GSM3619624_STAR
        83.3%
        34.0
        GSM3619625
        80.8%
        GSM3619625_SRR8618443_1
        57.3%
        46%
        31.6
        GSM3619625_SRR8618443_2
        52.4%
        47%
        31.6
        GSM3619625_STAR
        85.0%
        26.9
        GSM3619626
        85.0%
        GSM3619626_SRR8618445_1
        74.2%
        46%
        37.9
        GSM3619626_SRR8618445_2
        70.4%
        47%
        37.9
        GSM3619626_STAR
        83.8%
        31.8
        GSM3619627
        84.9%
        GSM3619627_SRR8618446_1
        67.9%
        47%
        39.3
        GSM3619627_SRR8618446_2
        63.3%
        47%
        39.3
        GSM3619627_STAR
        85.4%
        33.6
        GSM3619628
        83.8%
        GSM3619628_SRR8618447_1
        68.0%
        46%
        42.3
        GSM3619628_SRR8618447_2
        63.6%
        47%
        42.3
        GSM3619628_STAR
        85.2%
        36.1
        GSM3619629
        85.8%
        GSM3619629_SRR8618448_1
        60.4%
        46%
        33.8
        GSM3619629_SRR8618448_2
        54.6%
        47%
        33.8
        GSM3619629_STAR
        87.6%
        29.6
        GSM3619630
        83.6%
        GSM3619630_SRR8618449_1
        60.1%
        47%
        34.2
        GSM3619630_SRR8618449_2
        55.1%
        47%
        34.2
        GSM3619630_STAR
        86.3%
        29.5
        GSM3619631
        78.5%
        GSM3619631_SRR8618450_1
        63.9%
        46%
        32.6
        GSM3619631_SRR8618450_2
        58.1%
        47%
        32.6
        GSM3619631_STAR
        82.1%
        26.8
        GSM3619632
        86.7%
        GSM3619632_SRR8618451_1
        65.6%
        46%
        37.5
        GSM3619632_SRR8618451_2
        60.0%
        47%
        37.5
        GSM3619632_STAR
        87.3%
        32.8
        GSM3619633
        86.2%
        GSM3619633_SRR8618452_1
        60.6%
        46%
        36.0
        GSM3619633_SRR8618452_2
        55.0%
        47%
        36.0
        GSM3619633_STAR
        87.8%
        31.6
        GSM3619634
        87.3%
        GSM3619634_SRR8618453_1
        62.1%
        46%
        36.3
        GSM3619634_SRR8618453_2
        55.7%
        47%
        36.3
        GSM3619634_STAR
        88.5%
        32.1
        GSM3619635
        87.0%
        GSM3619635_SRR8618454_1
        74.0%
        47%
        37.7
        GSM3619635_SRR8618454_2
        67.8%
        48%
        37.7
        GSM3619635_STAR
        86.2%
        32.5
        GSM3619636_SRR8618455_1
        95.5%
        42%
        47.4
        GSM3619636_SRR8618455_2
        79.8%
        44%
        47.4
        GSM3619636_STAR
        23.3%
        11.1
        GSM3619637
        88.7%
        GSM3619637_SRR8618456_1
        89.9%
        41%
        35.1
        GSM3619637_SRR8618456_2
        86.9%
        41%
        35.1
        GSM3619637_STAR
        89.0%
        31.2
        GSM3619638
        89.6%
        GSM3619638_SRR8618457_1
        90.9%
        41%
        31.7
        GSM3619638_SRR8618457_2
        87.9%
        41%
        31.7
        GSM3619638_STAR
        89.2%
        28.3
        GSM3619639
        87.4%
        GSM3619639_SRR8618458_1
        85.6%
        42%
        41.4
        GSM3619639_SRR8618458_2
        82.0%
        43%
        41.4
        GSM3619639_STAR
        87.9%
        36.4
        GSM3619640
        84.7%
        GSM3619640_SRR8618459_1
        81.7%
        44%
        35.4
        GSM3619640_SRR8618459_2
        77.5%
        44%
        35.4
        GSM3619640_STAR
        85.1%
        30.1
        GSM3619641
        88.3%
        GSM3619641_SRR8618460_1
        89.1%
        41%
        31.3
        GSM3619641_SRR8618460_2
        86.0%
        41%
        31.3
        GSM3619641_STAR
        88.8%
        27.8
        GSM3619642
        86.2%
        GSM3619642_SRR8618461_1
        83.5%
        43%
        37.6
        GSM3619642_SRR8618461_2
        79.9%
        44%
        37.6
        GSM3619642_STAR
        86.8%
        32.6
        GSM3619643
        83.6%
        GSM3619643_SRR8618462_1
        86.4%
        43%
        35.5
        GSM3619643_SRR8618462_2
        81.7%
        44%
        35.5
        GSM3619643_STAR
        84.3%
        29.9
        GSM3619644
        83.2%
        GSM3619644_SRR8618463_1
        82.4%
        43%
        32.7
        GSM3619644_SRR8618463_2
        78.6%
        44%
        32.7
        GSM3619644_STAR
        84.1%
        27.5
        GSM3619645
        78.9%
        GSM3619645_SRR8618464_1
        87.9%
        42%
        37.3
        GSM3619645_SRR8618464_2
        83.6%
        43%
        37.3
        GSM3619645_STAR
        80.5%
        30.1
        GSM3619646
        85.6%
        GSM3619646_SRR8618465_1
        83.4%
        42%
        35.1
        GSM3619646_SRR8618465_2
        79.9%
        43%
        35.1
        GSM3619646_STAR
        86.6%
        30.4
        GSM3619647
        84.0%
        GSM3619647_SRR8618467_1
        87.0%
        41%
        30.2
        GSM3619647_SRR8618467_2
        83.8%
        42%
        30.2
        GSM3619647_STAR
        85.2%
        25.7
        GSM3619648
        80.1%
        GSM3619648_SRR8618468_1
        94.3%
        40%
        33.5
        GSM3619648_SRR8618468_2
        87.8%
        41%
        33.5
        GSM3619648_STAR
        81.2%
        27.2
        GSM3619649
        88.8%
        GSM3619649_SRR8618469_1
        93.9%
        40%
        38.0
        GSM3619649_SRR8618469_2
        90.8%
        41%
        38.0
        GSM3619649_STAR
        88.8%
        33.7
        GSM3619650
        87.4%
        GSM3619650_SRR8618470_1
        91.9%
        41%
        34.9
        GSM3619650_SRR8618470_2
        88.7%
        42%
        34.9
        GSM3619650_STAR
        87.8%
        30.7
        GSM3619651
        82.1%
        GSM3619651_SRR8618471_1
        92.9%
        41%
        38.1
        GSM3619651_SRR8618471_2
        88.5%
        42%
        38.1
        GSM3619651_STAR
        81.4%
        31.1
        GSM3619652
        83.9%
        GSM3619652_SRR8618472_1
        91.0%
        41%
        39.0
        GSM3619652_SRR8618472_2
        86.5%
        42%
        39.0
        GSM3619652_STAR
        83.8%
        32.7
        GSM3619653
        86.8%
        GSM3619653_SRR8618473_1
        91.6%
        41%
        36.8
        GSM3619653_SRR8618473_2
        86.7%
        41%
        36.8
        GSM3619653_STAR
        86.8%
        32.0
        GSM3619654
        86.4%
        GSM3619654_SRR8618474_1
        92.4%
        41%
        36.5
        GSM3619654_SRR8618474_2
        87.7%
        42%
        36.5
        GSM3619654_STAR
        86.7%
        31.6
        GSM3619655
        71.1%
        GSM3619655_SRR8618475_1
        94.5%
        41%
        53.0
        GSM3619655_SRR8618475_2
        84.7%
        43%
        53.0
        GSM3619655_STAR
        73.0%
        38.7

        Rsem

        Rsem RSEM (RNA-Seq by Expectation-Maximization) is a software package forestimating gene and isoform expression levels from RNA-Seq data.DOI: 10.1186/1471-2105-12-323.

        Mapped Reads

        A breakdown of how all reads were aligned for each sample.

        loading..

        Multimapping rates

        A frequency histogram showing how many reads were aligned to n reference regions.

        In an ideal world, every sequence reads would align uniquely to a single location in the reference. However, due to factors such as repeititve sequences, short reads and sequencing errors, reads can be align to the reference 0, 1 or more times. This plot shows the frequency of each factor of multimapping. Good samples should have the majority of reads aligning once.

        loading..

        STAR

        STAR is an ultrafast universal RNA-seq aligner.DOI: 10.1093/bioinformatics/bts635.

        Alignment Scores

        loading..

        FastQ Screen

        Version: 0.15.1

        FastQ Screen allows you to screen a library of sequences in FastQ format against a set of sequence databases so you can see if the composition of the library matches with what you expect.DOI: 10.12688/f1000research.15931.2.

        Mapped Reads

        loading..

        FastQC

        Version: 0.11.9

        FastQC is a quality control tool for high throughput sequence data, written by Simon Andrews at the Babraham Institute in Cambridge.

        Sequence Counts

        Sequence counts for each sample. Duplicate read counts are an estimate only.

        This plot show the total number of reads, broken down into unique and duplicate if possible (only more recent versions of FastQC give duplicate info).

        You can read more about duplicate calculation in the FastQC documentation. A small part has been copied here for convenience:

        Only sequences which first appear in the first 100,000 sequences in each file are analysed. This should be enough to get a good impression for the duplication levels in the whole file. Each sequence is tracked to the end of the file to give a representative count of the overall duplication level.

        The duplication detection requires an exact sequence match over the whole length of the sequence. Any reads over 75bp in length are truncated to 50bp for this analysis.

        loading..

        Sequence Quality Histograms

        The mean quality value across each base position in the read.

        To enable multiple samples to be plotted on the same graph, only the mean quality scores are plotted (unlike the box plots seen in FastQC reports).

        Taken from the FastQC help:

        The y-axis on the graph shows the quality scores. The higher the score, the better the base call. The background of the graph divides the y axis into very good quality calls (green), calls of reasonable quality (orange), and calls of poor quality (red). The quality of calls on most platforms will degrade as the run progresses, so it is common to see base calls falling into the orange area towards the end of a read.

        loading..

        Per Sequence Quality Scores

        The number of reads with average quality scores. Shows if a subset of reads has poor quality.

        From the FastQC help:

        The per sequence quality score report allows you to see if a subset of your sequences have universally low quality values. It is often the case that a subset of sequences will have universally poor quality, however these should represent only a small percentage of the total sequences.

        loading..

        Per Base Sequence Content

        The proportion of each base position for which each of the four normal DNA bases has been called.

        To enable multiple samples to be shown in a single plot, the base composition data is shown as a heatmap. The colours represent the balance between the four bases: an even distribution should give an even muddy brown colour. Hover over the plot to see the percentage of the four bases under the cursor.

        To see the data as a line plot, as in the original FastQC graph, click on a sample track.

        From the FastQC help:

        Per Base Sequence Content plots out the proportion of each base position in a file for which each of the four normal DNA bases has been called.

        In a random library you would expect that there would be little to no difference between the different bases of a sequence run, so the lines in this plot should run parallel with each other. The relative amount of each base should reflect the overall amount of these bases in your genome, but in any case they should not be hugely imbalanced from each other.

        It's worth noting that some types of library will always produce biased sequence composition, normally at the start of the read. Libraries produced by priming using random hexamers (including nearly all RNA-Seq libraries) and those which were fragmented using transposases inherit an intrinsic bias in the positions at which reads start. This bias does not concern an absolute sequence, but instead provides enrichement of a number of different K-mers at the 5' end of the reads. Whilst this is a true technical bias, it isn't something which can be corrected by trimming and in most cases doesn't seem to adversely affect the downstream analysis.

        Click a sample row to see a line plot for that dataset.
        Rollover for sample name
        Position: -
        %T: -
        %C: -
        %A: -
        %G: -

        Per Sequence GC Content

        The average GC content of reads. Normal random library typically have a roughly normal distribution of GC content.

        From the FastQC help:

        This module measures the GC content across the whole length of each sequence in a file and compares it to a modelled normal distribution of GC content.

        In a normal random library you would expect to see a roughly normal distribution of GC content where the central peak corresponds to the overall GC content of the underlying genome. Since we don't know the the GC content of the genome the modal GC content is calculated from the observed data and used to build a reference distribution.

        An unusually shaped distribution could indicate a contaminated library or some other kinds of biased subset. A normal distribution which is shifted indicates some systematic bias which is independent of base position. If there is a systematic bias which creates a shifted normal distribution then this won't be flagged as an error by the module since it doesn't know what your genome's GC content should be.

        loading..

        Per Base N Content

        The percentage of base calls at each position for which an N was called.

        From the FastQC help:

        If a sequencer is unable to make a base call with sufficient confidence then it will normally substitute an N rather than a conventional base call. This graph shows the percentage of base calls at each position for which an N was called.

        It's not unusual to see a very low proportion of Ns appearing in a sequence, especially nearer the end of a sequence. However, if this proportion rises above a few percent it suggests that the analysis pipeline was unable to interpret the data well enough to make valid base calls.

        loading..

        Sequence Length Distribution

        All samples have sequences of a single length (126bp).

        Sequence Duplication Levels

        The relative level of duplication found for every sequence.

        From the FastQC Help:

        In a diverse library most sequences will occur only once in the final set. A low level of duplication may indicate a very high level of coverage of the target sequence, but a high level of duplication is more likely to indicate some kind of enrichment bias (eg PCR over amplification). This graph shows the degree of duplication for every sequence in a library: the relative number of sequences with different degrees of duplication.

        Only sequences which first appear in the first 100,000 sequences in each file are analysed. This should be enough to get a good impression for the duplication levels in the whole file. Each sequence is tracked to the end of the file to give a representative count of the overall duplication level.

        The duplication detection requires an exact sequence match over the whole length of the sequence. Any reads over 75bp in length are truncated to 50bp for this analysis.

        In a properly diverse library most sequences should fall into the far left of the plot in both the red and blue lines. A general level of enrichment, indicating broad oversequencing in the library will tend to flatten the lines, lowering the low end and generally raising other categories. More specific enrichments of subsets, or the presence of low complexity contaminants will tend to produce spikes towards the right of the plot.

        loading..

        Overrepresented sequences by sample

        The total amount of overrepresented sequences found in each library.

        FastQC calculates and lists overrepresented sequences in FastQ files. It would not be possible to show this for all samples in a MultiQC report, so instead this plot shows the number of sequences categorized as overrepresented.

        Sometimes, a single sequence may account for a large number of reads in a dataset. To show this, the bars are split into two: the first shows the overrepresented reads that come from the single most common sequence. The second shows the total count from all remaining overrepresented sequences.

        From the FastQC Help:

        A normal high-throughput library will contain a diverse set of sequences, with no individual sequence making up a tiny fraction of the whole. Finding that a single sequence is very overrepresented in the set either means that it is highly biologically significant, or indicates that the library is contaminated, or not as diverse as you expected.

        FastQC lists all the sequences which make up more than 0.1% of the total. To conserve memory only sequences which appear in the first 100,000 sequences are tracked to the end of the file. It is therefore possible that a sequence which is overrepresented but doesn't appear at the start of the file for some reason could be missed by this module.

        loading..

        Top overrepresented sequences

        Top overrepresented sequences across all samples. The table shows 20 most overrepresented sequences across all samples, ranked by the number of samples they occur in.

        Showing 20/20 rows and 3/3 columns.
        Overrepresented sequenceSamplesOccurrences% of all reads
        GATCGGAAGAGCGTCGTGTAGGGAAAGAGTGTAGATCTCGGTGGTCGCCG
        38
        43766034
        1.4955%
        AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
        25
        3922109
        0.1340%
        GGGGCATCCATGCAGTCATTCTAGGTTAGTTGAAGAGTAGGAAATTGAGA
        20
        2755122
        0.0941%
        CTGATGTCTATAAGTACTAGGGTAGCTCCTCCGATTAGATGCATTAATAG
        19
        1538070
        0.0526%
        GTCAAAGCATAGGTCTTCATAGTCAGTATATTCATAGCTTCAGTATCATT
        19
        1688923
        0.0577%
        AAAAAATGTTATGTTTACACCTACAAATATAATGGCAAAGTGGGCTTTTG
        19
        1578314
        0.0539%
        GTTTGCTGTTAGTCGTACTGCTAGTGCTATCGGTTGAATAAATAGGCTGA
        19
        1260856
        0.0431%
        CTTTAGCCCACTTCTTACCGCAAGGAACCCCCATCTCACTAATTCCCATA
        19
        2084365
        0.0712%
        GCCACATCACCTATCATAGAAGAACTTACAAACTTTCATGACCACACCCT
        19
        1484048
        0.0507%
        ATAAGTACTAGGGTAGCTCCTCCGATTAGATGCATTAATAGATGGCCTGC
        18
        932667
        0.0319%
        CGAAAATCTATTTGCCTCTTTCATTACCCCCACAATAATAGGTCTACCAA
        18
        1154459
        0.0394%
        CTCGTCGTTACTCTGATTATCCAGATGCTTATACCACATGAAATACAGTC
        18
        1122364
        0.0384%
        GGAACCCCCATCTCACTAATTCCCATACTAATCATCATCGAAACTATCAG
        18
        971035
        0.0332%
        CGGGTGTCTACATCTAGGCCTACTGTGAATATGTGATGTGCTCATACAAT
        17
        1372013
        0.0469%
        GGAAGAAGCCCTAGAAGGTTGGTTGAGCCGATAAATATAATTAGGGATAC
        17
        1021793
        0.0349%
        GGCAAATTCAAGTACTGTAAGTAGAAGTAGAATAATAAATGTAATTGTAG
        17
        943038
        0.0322%
        GCGGAATGTTAAGCTGCGTTGTTTTGAGGTATGCAGGAATGGTAGGAAGG
        17
        859986
        0.0294%
        CTTACTAGAAGGGTGAATACATAGGCTTGAATTAAGGCTACGGCAAATTC
        16
        923232
        0.0315%
        GTAAATTCCGTCTGAGATAGAAAATGATGTTTCGAAATACTCTGAGGCTT
        16
        712290
        0.0243%
        TCTACATCTAGGCCTACTGTGAATATGTGATGTGCTCATACAATAAATCC
        15
        1039519
        0.0355%

        Adapter Content

        The cumulative percentage count of the proportion of your library which has seen each of the adapter sequences at each position.

        Note that only samples with ≥ 0.1% adapter contamination are shown.

        There may be several lines per sample, as one is shown for each adapter detected in the file.

        From the FastQC Help:

        The plot shows a cumulative percentage count of the proportion of your library which has seen each of the adapter sequences at each position. Once a sequence has been seen in a read it is counted as being present right through to the end of the read so the percentages you see will only increase as the read length goes on.

        loading..

        Status Checks

        Status for each FastQC section showing whether results seem entirely normal (green), slightly abnormal (orange) or very unusual (red).

        FastQC assigns a status for each section of the report. These give a quick evaluation of whether the results of the analysis seem entirely normal (green), slightly abnormal (orange) or very unusual (red).

        It is important to stress that although the analysis results appear to give a pass/fail result, these evaluations must be taken in the context of what you expect from your library. A 'normal' sample as far as FastQC is concerned is random and diverse. Some experiments may be expected to produce libraries which are biased in particular ways. You should treat the summary evaluations therefore as pointers to where you should concentrate your attention and understand why your library may not look random and diverse.

        Specific guidance on how to interpret the output of each module can be found in the relevant report section, or in the FastQC help.

        In this heatmap, we summarise all of these into a single heatmap for a quick overview. Note that not all FastQC sections have plots in MultiQC reports, but all status checks are shown in this heatmap.

        loading..

        Software Versions

        Software Versions lists versions of software tools extracted from file contents.

        SoftwareVersion
        FastQ Screen0.15.1
        FastQC0.11.9